{"id":2796,"date":"2026-11-28T09:10:00","date_gmt":"2026-11-28T01:10:00","guid":{"rendered":"https:\/\/lemaele.com\/blog\/micro-switch-terminal-plating-adhesion-evidence\/"},"modified":"2026-11-28T01:43:15","modified_gmt":"2026-11-27T17:43:15","slug":"micro-switch-terminal-plating-adhesion-evidence","status":"publish","type":"post","link":"https:\/\/lemaele.com\/de\/blog\/micro-switch-terminal-plating-adhesion-evidence\/","title":{"rendered":"Haftfestigkeit der Beschichtung von Mikroschalter-Anschl\u00fcssen: Nachweise f\u00fcr Eink\u00e4ufer"},"content":{"rendered":"<style>.lema-article{min-width:0;max-width:100%;overflow-wrap:anywhere}.lema-article img{max-width:100%;height:auto}.lema-table{max-width:100%;overflow-x:auto}.lema-table table{border-collapse:collapse;min-width:640px;width:100%}.lema-table th,.lema-table td{padding:12px;border:1px solid #ddd;text-align:left;vertical-align:top}.lema-video{position:relative;padding-bottom:56.25%;height:0}.lema-video iframe{position:absolute;inset:0;width:100%;height:100%;border:0}<\/style>\n<div class=\"lema-article\">\n<p>Micro switch terminal plating adhesion evidence should connect the actual terminal finish, the approved evaluation method and a traceable sample to a clearly recorded result. A shiny terminal is not proof that its surface layer is securely bonded. A scratch is not automatically proof of poor adhesion either. Before requesting a test, confirm whether the supplied terminal is plated, identify the coating and base material through controlled documents, and agree what evidence will answer the purchasing question. This guide uses the KW7 product as a visible reference without assigning it an unverified plating system, acceptance limit or certification.<\/p>\n<aside class=\"lema-quick-answer\" style=\"border-left:4px solid var(--lema-orange);padding:14px 18px;margin:22px 0;font-weight:400\"><strong>Quick answer:<\/strong> Confirm the terminal finish and substrate, then request an applicable adhesion method with traceable samples and results. Appearance, coating thickness and brief connection checks answer different questions.<\/aside>\n<h2>Identify the terminal construction before selecting a test<\/h2>\n<p>The <a href=\"https:\/\/lemaele.com\/product\/kw7-series-micro-switch\/\">Lemaele KW7 series micro switch<\/a> reference includes a plunger version and a roller lever version with projecting metal terminal tabs. These tabs are external connections, separate from the internal switching contacts. An adhesion report for an internal contact does not automatically describe the external tab. Record the exact order code, terminal option, drawing revision and lot before comparing documents. Identify the terminal surface being evaluated with an overall photograph and a location annotation.<\/p>\n<p>Ask the supplier to confirm the finish designation, substrate and any relevant processing sequence. Color alone cannot establish tin, nickel, silver or another metal. If a finish is not specified, first resolve the construction requirement rather than commissioning a test with an assumed material. The broader <a href=\"https:\/\/lemaele.com\/blog\/industrial-micro-switch-selection-guide\/\">industrial micro switch selection guide<\/a> helps organize the whole component choice; this article addresses whether a particular terminal surface layer has suitable supporting evidence.<\/p>\n<h2>Separate adhesion from thickness and connection performance<\/h2>\n<p>Adhesion concerns attachment of the coating to the underlying surface. Thickness concerns how much coating is present at a defined location. A thickness reading can meet its requirement without resolving adhesion, and an adhesion observation does not establish coating thickness. Request these results as separate evidence items. Use the existing <a href=\"https:\/\/lemaele.com\/blog\/micro-switch-terminal-coating-thickness-report\/\">terminal coating thickness report checklist<\/a> when reviewing measurement locations, coating layers and dimensional reporting. Do not use its values as a substitute for a bonding evaluation.<\/p>\n<p>Connection behavior is another separate question. A terminal that accepts a mating connector or solder during a brief check has not necessarily demonstrated long term coating integrity. Conversely, a local handling mark does not establish an electrical failure. Keep observations about lifting, cracking, loose particles and connection symptoms distinct in the report. This separation helps the supplier investigate the correct issue and prevents a convenient but incomplete test from being described as proof of every terminal property.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/lemaele.com\/wp-content\/uploads\/2026\/11\/lema-micro-switch-terminal-plating-adhesion-evidence-body1-20261127.webp\" alt=\"Close view of KW7 silver terminal tabs and their holes under inspection lighting\" loading=\"lazy\" width=\"1672\" height=\"941\" title=\"\"><figcaption>Close view of KW7 silver terminal tabs and their holes under inspection lighting. Product-reference illustration; not a test result or approved test fixture.<\/figcaption><\/figure>\n<div class=\"lema-table\">\n<table>\n<thead>\n<tr>\n<th>Evidence item<\/th>\n<th>What to verify<\/th>\n<th>Decision supported<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Construction<\/td>\n<td>Finish and substrate confirmed by controlled supplier documents<\/td>\n<td>Method applicability can be reviewed<\/td>\n<\/tr>\n<tr>\n<td>Representation<\/td>\n<td>Finished terminal or documented equivalent specimen<\/td>\n<td>Report relates to the ordered part<\/td>\n<\/tr>\n<tr>\n<td>Procedure<\/td>\n<td>Method revision, location and permitted deviations<\/td>\n<td>Results can be interpreted consistently<\/td>\n<\/tr>\n<tr>\n<td>Observation<\/td>\n<td>Before and after images with sample identity<\/td>\n<td>Lifting or separation is described factually<\/td>\n<\/tr>\n<tr>\n<td>Disposition<\/td>\n<td>Agreed criterion and named acceptance authority<\/td>\n<td>Shipment decision is traceable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Agree a method that represents the supplied geometry<\/h2>\n<p>The public scope of <a href=\"https:\/\/store.astm.org\/standards\/b571\" rel=\"noopener\" target=\"_blank\">ASTM B571 qualitative adhesion testing<\/a> describes several approaches and emphasizes selecting the method and acceptance interpretation for the application. It is background for specifying evidence, not proof that KW7 terminals have been tested to it. A method suitable for one coating and substrate may not suit another. Ask the responsible laboratory to confirm applicability to the actual terminal construction before approving an inspection instruction.<\/p>\n<p>Terminal size and access matter. A narrow tab attached to a plastic body may not permit a procedure intended for a flat loose specimen. The laboratory should explain whether a finished terminal, a separately supplied terminal or an agreed representative panel will be evaluated. If a panel is proposed, request documented material and process equivalence. Do not assume that a generic plated coupon represents the same preparation, forming, coating and postprocessing history as the delivered terminals.<\/p>\n<h2>Review surface preparation evidence without guessing the cause<\/h2>\n<p>Surface condition and preparation are relevant parts of a coating investigation, but a photograph rarely identifies which manufacturing step produced a separation. The National Physical Laboratory <a href=\"https:\/\/eprintspublications.npl.co.uk\/3927\/1\/MGPG%20100.pdf\" rel=\"noopener\" target=\"_blank\">guide to non-destructive assessment of coating adhesion<\/a> describes assessment approaches and the need to consider their suitability. It supports asking how a proposed method relates to the coating system; it does not establish a particular cleaning chemistry, roughness or treatment for KW7. Keep supplier process details and laboratory observations separate from proposed explanations.<\/p>\n<p>If loose material is found, photograph the as received condition before cleaning or attempting to remove it. Record whether the sample has been soldered, heated, formed, mated, stored in unusual conditions or otherwise handled after receipt. Such history may help frame the investigation. Describe an observed flake or lifted edge factually and let the supplier identify the layer and origin. Do not call a visible particle detached plating until its relationship to the terminal surface is established.<\/p>\n<h2>Preserve the assembled switch and select sacrificial samples<\/h2>\n<p>Destructive or deforming evaluations belong on samples specifically approved for that purpose. Do not bend a terminal on a production switch and then return the altered component to stock. The external tab transmits load to the assembly, so an uncontrolled hand test can introduce damage unrelated to the original concern. Preserve a separate as received reference and identify every sample sent for laboratory work. Any installed equipment must be made safe through the equipment owner\u2019s established procedure before access.<\/p>\n<p>Agree in advance whether the tested sample will be sectioned, deformed, heated or otherwise consumed. Record its original orientation and the terminal under review. The <a href=\"https:\/\/lemaele.com\/blog\/micro-switch-terminal-edge-burr-inspection\/\">terminal edge burr inspection guide<\/a> addresses a different surface geometry issue; do not use a burr removal operation as an adhesion test. Scraping, polishing or uncontrolled tape pulling can erase the very evidence needed to distinguish an edge condition from a coating problem.<\/p>\n<h2>Ask for a report that can be traced to the order<\/h2>\n<p>A useful laboratory report identifies the customer request, sample identity, exact method and revision, examined location and any departure from the agreed procedure. It should state the sample condition before evaluation and the observation after it. If magnified images are supplied, retain an overall view so the close view can be located on the terminal. Ask for scale information and consistent image identification rather than relying on an isolated picture with no connection to the purchased part.<\/p>\n<p>The conclusion should be linked to the requirement actually invoked for the order. A statement such as acceptable is incomplete if the method, criterion or part identity is missing. Where interpretation is qualitative, request a description of what was observed and the agreed decision rule. A report can also record an inconclusive outcome when access, sample damage or uncertain construction prevents a sound decision. That is more useful than an unsupported pass based only on a neat looking surface.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/lemaele.com\/wp-content\/uploads\/2026\/11\/lema-micro-switch-terminal-plating-adhesion-evidence-body2-20261127.webp\" alt=\"KW7 plunger and roller lever micro switch variants beside traceable sample containers\" loading=\"lazy\" width=\"1536\" height=\"1024\" title=\"\"><figcaption>KW7 plunger and roller lever micro switch variants beside traceable sample containers. Product-reference illustration; not a test result or approved test fixture.<\/figcaption><\/figure>\n<h2>Handle a disagreement through controlled comparison<\/h2>\n<p>If buyer and supplier reach different conclusions, first compare specimen identity, preparation, viewing conditions and the exact procedure used. A result from a formed terminal may not be comparable with one from an unrelated flat coupon. A photograph taken before handling may not describe the same condition as an image captured after mating or soldering. Resolve these differences before repeating tests. Keep any follow up evaluation linked to the initial samples and the original concern.<\/p>\n<p>When a further assessment is justified, agree the sample selection and evidence package together. The purpose is to answer the unresolved bonding question, not to keep changing methods until a favorable result appears. Preserve the full record, including unfavorable and inconclusive observations. Ask the supplier to distinguish containment of the affected shipment from investigation of the manufacturing cause. A replacement decision and a confirmed root cause can occur at different times and should not be merged in the record.<\/p>\n<h2>References<\/h2>\n<ul>\n<li><a href=\"https:\/\/store.astm.org\/standards\/b571\" rel=\"noopener\" target=\"_blank\">ASTM International \u2014 Qualitative Adhesion Testing of Metallic Coatings<\/a><\/li>\n<li><a href=\"https:\/\/eprintspublications.npl.co.uk\/3927\/1\/MGPG%20100.pdf\" rel=\"noopener\" target=\"_blank\">National Physical Laboratory \u2014 Non-destructive Assessment of Coating Adhesion<\/a><\/li>\n<\/ul>\n<h2>Specify useful evidence for repeat purchases<\/h2>\n<p>A purchase specification can identify the terminal option, controlled finish documentation, applicable evaluation method, sample traceability and acceptance authority. Where representative panels are allowed, state how their relationship to delivered parts will be demonstrated. If processing changes after the original evaluation, request an assessment of whether the old evidence still applies. Avoid demanding a generic adhesion certificate with no connection to the ordered terminal; a short traceable report is more useful than an impressive unrelated document.<\/p>\n<p>For a new inquiry, send the intended connection process, relevant handling or forming steps, drawing requirement and the reason adhesion evidence is needed. Lemaele can then be asked to confirm the available terminal construction and supporting documentation for that configuration. Do not assume a finish, test method or result from this illustrated workflow. The final purchasing decision should join the agreed requirement, the actual sample, the chosen method and the recorded observation into one reviewable chain.<\/p>\n<h2>Further learning<\/h2>\n<p>This NPTEL lecture by IIT Kharagpur explains coating adhesion assessment as educational background. It does not demonstrate a KW7 terminal test, identify its finish or provide an acceptance result.<\/p>\n<div class=\"lema-video\"><iframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/CwKZL2qF9t4\" title=\"Mod-01 Lec-38 Assessment of Adhesion of Coating\" loading=\"lazy\" allow=\"encrypted-media; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<h2>Frequently asked questions<\/h2>\n<h3>Does a bright terminal prove good plating adhesion?<\/h3>\n<p>No. Appearance alone does not establish bonding. Confirm the surface construction and review evidence from a method agreed for the actual coating, substrate and geometry.<\/p>\n<h3>Can a coating thickness report replace adhesion evidence?<\/h3>\n<p>No. Thickness and bonding answer different questions. Review each against its own requirement and identify the same terminal configuration and lot where applicable.<\/p>\n<h3>Should receiving staff bend a terminal to check the finish?<\/h3>\n<p>Do not improvise a destructive check on production stock. Use an approved procedure and sacrificial samples selected for the evaluation, while retaining an as received reference.<\/p>\n<h3>Does ASTM B571 automatically apply to every KW7 order?<\/h3>\n<p>No. Its public scope is method background. Applicability, procedure and acceptance interpretation must be agreed for the ordered construction; no KW7 compliance or result is asserted here.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Does a bright terminal prove good plating adhesion?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Appearance alone does not establish bonding. Confirm the surface construction and review evidence from a method agreed for the actual coating, substrate and geometry.\"}}, {\"@type\": \"Question\", \"name\": \"Can a coating thickness report replace adhesion evidence?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Thickness and bonding answer different questions. Review each against its own requirement and identify the same terminal configuration and lot where applicable.\"}}, {\"@type\": \"Question\", \"name\": \"Should receiving staff bend a terminal to check the finish?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not improvise a destructive check on production stock. Use an approved procedure and sacrificial samples selected for the evaluation, while retaining an as received reference.\"}}, {\"@type\": \"Question\", \"name\": \"Does ASTM B571 automatically apply to every KW7 order?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Its public scope is method background. Applicability, procedure and acceptance interpretation must be agreed for the ordered construction; no KW7 compliance or result is asserted here.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pr\u00fcfen Sie die Nachweise zur Haftfestigkeit der Anschlussbeschichtung von Mikroschalterklemmen anhand der Oberfl\u00e4chenbeschichtungsidentifikation, geeigneter Pr\u00fcfverfahren, r\u00fcckverfolgbarer Muster und aussagekr\u00e4ftiger Lieferantenberichte.<\/p>","protected":false},"author":9,"featured_media":2793,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[51],"class_list":["post-2796","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-micro-switch"],"_links":{"self":[{"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/posts\/2796","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/comments?post=2796"}],"version-history":[{"count":2,"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/posts\/2796\/revisions"}],"predecessor-version":[{"id":2850,"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/posts\/2796\/revisions\/2850"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/media\/2793"}],"wp:attachment":[{"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/media?parent=2796"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/categories?post=2796"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lemaele.com\/de\/wp-json\/wp\/v2\/tags?post=2796"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}