{"id":2687,"date":"2026-11-23T09:10:00","date_gmt":"2026-11-23T01:10:00","guid":{"rendered":"https:\/\/lemaele.com\/blog\/micro-switch-terminal-hole-position-inspection\/"},"modified":"2026-11-22T01:41:26","modified_gmt":"2026-11-21T17:41:26","slug":"micro-switch-terminal-hole-position-inspection","status":"publish","type":"post","link":"https:\/\/lemaele.com\/es\/blog\/micro-switch-terminal-hole-position-inspection\/","title":{"rendered":"Posici\u00f3n del orificio del terminal del microinterruptor: Inspeccionar la caracter\u00edstica de conexi\u00f3n"},"content":{"rendered":"<style>.lema-article{min-width:0;max-width:100%;overflow-wrap:anywhere}.lema-article img{max-width:100%;height:auto}.lema-table{max-width:100%;overflow-x:auto}.lema-table table{border-collapse:collapse;min-width:640px;width:100%}.lema-table th,.lema-table td{padding:12px;border:1px solid #ddd;text-align:left;vertical-align:top}.lema-video{position:relative;padding-bottom:56.25%;height:0}.lema-video iframe{position:absolute;inset:0;width:100%;height:100%;border:0}<\/style>\n<div class=\"lema-article\">\n<p>Micro switch terminal hole position inspection checks the location of the hole in an external connection terminal against the approved drawing and its defined references. It is a different task from checking the mounting holes in the switch housing. Identify the ordered terminal version, establish how the sample will be held, and request a report that separates hole size, hole location and terminal deformation. A wire passing through the hole is not a dimensional acceptance test. This guide uses the visible Lemaele KW7 connection terminals as a product reference without assigning an unverified hole diameter, location tolerance or connection method.<\/p>\n<h2>Identify the terminal feature before requesting measurements<\/h2>\n<p>The first inspection photograph should make the feature unambiguous. Show the whole switch, then identify the particular metal terminal and the opening under review. Distinguish that opening from a hole in the plastic body, a recess in the actuator or a gap between terminals. Label the terminal according to the controlled drawing rather than assuming a connection identity from its physical position.<\/p>\n<p>The <a href=\"https:\/\/lemaele.com\/product\/kw7-series-micro-switch\/\">KW7 series micro switch<\/a> page provides the real product family behind this inquiry. Its photograph shows external metal connection features, but a photograph cannot establish the exact terminal option supplied for an order. Obtain the selected model drawing, purchase description and revision before comparing samples. Do not transfer dimensions from a visually similar switch.<\/p>\n<h2>Separate hole size, position and terminal shape<\/h2>\n<p>A terminal opening can have an acceptable size while sitting in an unacceptable location. Conversely, its center can lie where intended while its edge is damaged or its size is unsuitable. A bent terminal introduces another question: whether the opening is displaced because the whole terminal has moved. Record these observations separately so that the supplier can investigate the actual feature.<\/p>\n<p>A useful receiving record contains the hole identifier, the intended reference features, the size requirement and the positional requirement as separate entries. If the drawing supplies only a general outline, ask which requirement controls acceptance. Do not invent a center distance by scaling a website image. Perspective, lens distortion and an uncertain image scale make that shortcut unsuitable for a purchasing decision.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/lemaele.com\/wp-content\/uploads\/2026\/11\/lema-micro-switch-terminal-hole-position-inspection-body1-20261122.webp\" alt=\"Close view of KW7 external terminal holes on an isolated sample\" loading=\"lazy\" width=\"1672\" height=\"941\" title=\"\"><figcaption>Close view of KW7 external terminal holes on an isolated sample. Product-reference illustration; not a test result or approved test fixture.<\/figcaption><\/figure>\n<div class=\"lema-table\">\n<table>\n<thead>\n<tr>\n<th>Evidence item<\/th>\n<th>What to verify<\/th>\n<th>Decision supported<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Terminal identity<\/td>\n<td>Exact hole and ordered terminal option<\/td>\n<td>Prevents inspection of the housing hole instead<\/td>\n<\/tr>\n<tr>\n<td>Drawing reference<\/td>\n<td>Revision, feature identifiers and alignment<\/td>\n<td>Defines the location requirement<\/td>\n<\/tr>\n<tr>\n<td>Received condition<\/td>\n<td>Bends, burrs, packaging and handling<\/td>\n<td>Preserves evidence before assembly<\/td>\n<\/tr>\n<tr>\n<td>Method suitability<\/td>\n<td>Visibility, support and measurement influence<\/td>\n<td>Establishes whether the result is usable<\/td>\n<\/tr>\n<tr>\n<td>Disposition<\/td>\n<td>Requirement, result and responsible approval<\/td>\n<td>Supports release, hold or clarification<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Use the drawing references rather than the easiest edge<\/h2>\n<p>The inspection setup must represent the reference system specified by the drawing. A convenient terminal edge may contain a stamping burr, rounded corner or local damage. It should not automatically become the origin for measuring the hole. Ask the metrology specialist which surfaces establish the alignment and how the switch is constrained without bending its terminals.<\/p>\n<p>NIST describes its <a href=\"https:\/\/www.nist.gov\/pml\/sensor-science\/dimensional-metrology\" rel=\"noopener\" target=\"_blank\">dimensional metrology work<\/a> as measurement science supporting dimensional quantities. This is background for the need for a suitable measurement process, not a source of KW7 acceptance tolerances. When requesting a supplier report, specify the drawing revision and feature identifiers; let the responsible laboratory explain the method and its limitations.<\/p>\n<h2>Choose a method that can see the relevant edges<\/h2>\n<p>For a small terminal opening, optical access, contrast and focus can determine whether the measured edge represents the intended feature. A shadow or bright reflection is not necessarily the physical boundary. Request a setup image showing the viewing direction and sample support. If the opening is not circular or its edge is obscured, the report should explain how the evaluated feature was constructed.<\/p>\n<p>Contact methods also need review. A probe or gauge that moves a flexible terminal can alter the feature being measured. A pin that enters an opening may answer a limited fit question while leaving location unanswered. The NPL <a href=\"https:\/\/eprintspublications.npl.co.uk\/2043\/1\/mgpg40.pdf\" rel=\"noopener\" target=\"_blank\">guide to callipers and micrometers<\/a> provides general measurement practice; it does not make either instrument automatically suitable for this positional inspection.<\/p>\n<h2>Preserve the received condition before handling<\/h2>\n<p>Keep samples unpowered and disconnected. Photograph packaging, sample identity and terminal orientation before straightening, inserting a wire or fitting a connector. Those actions can change the evidence. If a terminal is already bent, record the observation and segregate the sample rather than attempting to restore it to the expected shape.<\/p>\n<p>Assign a sample identifier that follows the part through photographs, readings and disposition. When samples come from different bags or cartons, preserve that relationship. A report combining measurements from one specimen with photographs of another makes later investigation harder. Record whether the switch was received loose, assembled in equipment or removed from an installation.<\/p>\n<h2>Build an inspection record that supports a decision<\/h2>\n<p>Ask for actual reported results against the controlled requirements, not simply a stamp saying dimensions checked. The record should identify which terminal and which hole were evaluated. It should also identify the method, instrument, fixture, drawing revision and sample condition. If measurement uncertainty affects a result close to a boundary, the laboratory should state the agreed decision rule.<\/p>\n<p>Repeat an observation only to resolve a defined question. For example, a controlled repeat after reseating a sample can help reveal setup sensitivity, but it should not become a search for the most favorable number. Keep the original reading and the reason for the repeat. Record an unresolved result as unresolved instead of averaging away a visible setup problem.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/lemaele.com\/wp-content\/uploads\/2026\/11\/lema-micro-switch-terminal-hole-position-inspection-body2-20261122.webp\" alt=\"KW7 samples separately identified beside a blank inspection card\" loading=\"lazy\" width=\"1536\" height=\"1024\" title=\"\"><figcaption>KW7 samples separately identified beside a blank inspection card. Product-reference illustration; not a test result or approved test fixture.<\/figcaption><\/figure>\n<h2>Keep adjacent inspections distinct<\/h2>\n<p>The <a href=\"https:\/\/lemaele.com\/blog\/micro-switch-mounting-hole-position-inspection\/\">housing mounting-hole guide<\/a> addresses the body features used to locate the switch in equipment. It should not be substituted for this terminal connection inspection. A mounting fixture may hold the body correctly while leaving a terminal bent or improperly supported.<\/p>\n<p>The <a href=\"https:\/\/lemaele.com\/blog\/micro-switch-terminal-coplanarity-inspection\/\">terminal coplanarity inspection guide<\/a> covers a different geometric relationship between terminals. Use both records if the purchase requires both characteristics. The <a href=\"https:\/\/lemaele.com\/blog\/micro-switch-terminal-types-guide\/\">terminal type selection guide<\/a> helps establish the selected connection style before dimensional inspection begins. Passing one characteristic does not establish the others.<\/p>\n<h2>Escalate differences without altering the sample<\/h2>\n<p>When an opening appears displaced, send the supplier the part identifier, drawing revision, photographs and the inspection setup. Explain whether the concern is location, opening size or deformation. Avoid describing the cause as a tooling problem until there is supporting manufacturing evidence. Handling damage, the wrong configuration and a measurement setup error require different corrective actions.<\/p>\n<p>Do not enlarge a terminal hole, bend the terminal into position or drill a replacement opening as a receiving correction. Such changes can affect the connection and invalidate the original evidence. Hold affected samples under the purchasing quality procedure while engineering and the supplier agree the disposition. Preserve accepted comparison samples without treating their appearance as an alternative specification.<\/p>\n<h2>Prepare a practical supplier inquiry<\/h2>\n<p>For a new order, include the equipment connection concept, selected terminal option, required drawing and the feature that needs inspection. State whether the report is for initial sample approval or routine receiving. Ask whether the supplier can provide a controlled drawing with the required feature identification before committing to a measurement plan.<\/p>\n<p>For an existing shipment, include lot identity, sample selection method and the observed symptom. If assembly fails, describe the mating component and preserve its identity too. An interference complaint is more useful when both sides of the interface are documented. Do not infer that every terminal opening is intended for a screw, wire loop or solder joint; confirm the approved connection method.<\/p>\n<h2>Close the inspection with a traceable disposition<\/h2>\n<p>An acceptable report connects the ordered part, drawing, sample and result. An inconclusive report identifies exactly what remains missing, such as a datum definition or suitable optical access. A nonconforming result identifies the controlled requirement involved and the authorized next action. These outcomes are more useful than a generic visual pass.<\/p>\n<p>Before releasing samples, check that photographs still match the inspected configuration and that the report has not mixed terminal and housing features. Retain the supplier clarification with the purchase record. Future inspection should use the agreed method and revision, while changes to terminal geometry or connection style trigger a fresh review rather than automatic reuse of the previous approval.<\/p>\n<h2>Further learning<\/h2>\n<p>The IIT KANPUR-NPTEL laboratory demonstration introduces dimensional measuring instruments. Use it as general measurement education; it does not specify a KW7 positional inspection setup or tolerance.<\/p>\n<div class=\"lema-video\"><iframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/vMgKQegeV24\" title=\"noc18-me62 Lec 12-Laboratory demonstration:Dial gauge and vernier,micrometer.\" loading=\"lazy\" allow=\"encrypted-media; picture-in-picture\" allowfullscreen><\/iframe><\/div>\n<h2>Frequently asked questions<\/h2>\n<h3>Is a terminal hole the same as a mounting hole?<\/h3>\n<p>No. A terminal hole is part of the metal connection feature; a mounting hole in the body serves a different interface. Identify the intended feature on the approved drawing.<\/p>\n<h3>Can I check position by inserting a wire?<\/h3>\n<p>Wire insertion can show a limited fit condition, but it does not establish the hole location relative to drawing references. Use the approved dimensional method.<\/p>\n<h3>What tolerance applies to KW7 terminal hole position?<\/h3>\n<p>This guide establishes no universal tolerance. Obtain the selected model drawing and purchasing requirements, including the relevant revision and decision rule.<\/p>\n<h3>Should I straighten a terminal before inspection?<\/h3>\n<p>Preserve and document the received condition first. Do not straighten or modify a suspect sample unless the responsible quality procedure expressly authorizes that action.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Is a terminal hole the same as a mounting hole?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. A terminal hole is part of the metal connection feature; a mounting hole in the body serves a different interface. Identify the intended feature on the approved drawing.\"}}, {\"@type\": \"Question\", \"name\": \"Can I check position by inserting a wire?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Wire insertion can show a limited fit condition, but it does not establish the hole location relative to drawing references. Use the approved dimensional method.\"}}, {\"@type\": \"Question\", \"name\": \"What tolerance applies to KW7 terminal hole position?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"This guide establishes no universal tolerance. Obtain the selected model drawing and purchasing requirements, including the relevant revision and decision rule.\"}}, {\"@type\": \"Question\", \"name\": \"Should I straighten a terminal before inspection?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Preserve and document the received condition first. Do not straighten or modify a suspect sample unless the responsible quality procedure expressly authorizes that action.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Inspeccionar la ubicaci\u00f3n del orificio del terminal del microinterruptor contra las referencias del dibujo controlado, preservar la condici\u00f3n recibida y solicitar evidencia dimensional KW7 trazable.<\/p>","protected":false},"author":9,"featured_media":2684,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[51],"class_list":["post-2687","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-micro-switch"],"_links":{"self":[{"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/posts\/2687","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/comments?post=2687"}],"version-history":[{"count":1,"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/posts\/2687\/revisions"}],"predecessor-version":[{"id":2688,"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/posts\/2687\/revisions\/2688"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/media\/2684"}],"wp:attachment":[{"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/media?parent=2687"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/categories?post=2687"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lemaele.com\/es\/wp-json\/wp\/v2\/tags?post=2687"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}