Micro switch terminal edge burr inspection should locate the questioned projection, identify the terminal version, and compare documented evidence with the agreed drawing or purchase requirement. Inspect the disconnected component before inserting a connector or attempting rework. A bright edge in a photograph does not prove a burr, and a switch that clicks does not prove its terminals are mechanically acceptable. For a buyer receiving KW7 series switches, the useful outcome is a traceable decision about the connection feature: accept against an established requirement, hold for clarification, or obtain an authorized corrective action.
Identify the terminal, not just the switch family
Das Mikroschalter der Serie KW7 provides the product context for this guide. Its published reference image shows basic plunger and roller-lever configurations with exposed flat terminals. The visible photograph establishes the general arrangement; it does not establish an allowable burr height, terminal alloy, coating thickness, or connector insertion force. Ask for the ordered terminal drawing and revision before using any of those properties as acceptance criteria.
Start the record with the purchase order, supplier designation, terminal configuration, shipment identification, and sample number. Take an overall view showing how the close-up relates to the housing. Identify whether the questioned area is a terminal tip, side edge, hole rim, or transition near the body. These positions can have different implications for mating, handling, and clearance; calling all of them a sharp terminal hides useful information.
Separate a burr from a reflection, coating feature, or damaged edge
A suspected burr may appear as a narrow projection beyond the intended edge. A highlight can resemble that projection when light reflects from a stamped or plated surface. Rotate the illumination and view the feature from another direction without bending the terminal. Retain the original image as well as a second view; heavily edited contrast or sharpening can create a misleading outline.
Das ESCC external visual inspection document for electrical connectors distinguishes burrs and bulges and considers functional consequences. It concerns a different component class and specification system. Its numerical limits, inspection conditions, and acceptance classifications are not requirements for a KW7 switch. Use it only as background for describing an edge feature and asking which connection function might be affected.

| Evidence item | Was zu überprüfen ist | Decision supported |
|---|---|---|
| Identity | Order, terminal version, lot, and sample reference | Connect the observation to the supplied configuration |
| Edge location | Tip, side, hole rim, or housing-side transition | Identify the potentially affected interface |
| Visual method | Lighting, orientation, magnification, and retained images | Make the observation reproducible |
| Requirement | Applicable drawing clause and revision | Separate evidence from an improvised limit |
| Disposition | Acceptance, hold, replacement, or approved rework | Close the record with accountable action |
Choose illumination that reveals the actual edge
Opaque metal terminals are viewed using light reflected from their surfaces. TU Berlin explains the distinction between reflected and transmitted illumination in its microscopy lighting overview. This explains the optical principle; it does not prescribe a switch inspection magnification. Select lighting and magnification that resolve the agreed characteristic, and record them so the supplier can reproduce the view.
Avoid letting a bright background erase the terminal outline. A contrasting clean background and stable support help make the edge visible. Include an orientation image, a detail image, and an indication of which terminal is shown. A scale used for measurement needs suitable calibration and the correct image plane; a ruler lying far below an elevated terminal is not a reliable dimensional reference. A photograph without an appropriate scale can still document appearance, provided it is not reported as a height measurement.
Inspect without creating a different defect
Keep the component disconnected from any energized circuit and handle it by the housing where practical. Use a support that does not load the terminals, hold the actuator depressed, or scratch the insulating body. Do not drag a finger along a suspected sharp edge. Do not scrape it with a probe merely to see whether it detaches: that changes the condition being investigated and may create debris.
Preserve one representative questioned sample in its received state. If cleaning, sectioning, or another investigative action is needed, agree on the method and ownership first. Record the condition before and after that action. An edge that disappears after wiping may have been contamination, but the wiping step and possible disturbance must remain in the report. Evidence should make the sequence understandable to someone who did not witness the inspection.
Relate the observation to the connection interface
For a quick-connect terminal, ask whether the questioned region enters the mating receptacle, lies beside the retained contact zone, or remains outside the engagement path. For a soldered connection, the relevant concerns and approved preparation can differ. Confirm the actual connection method rather than using whichever connector happens to be available at the bench. The Handbuch zu den Anschlussformen für Mikroschaltern helps establish that broader interface context.
Do not force a receptacle onto a suspect sample as an informal pass/fail test. An insertion attempt can flatten a projection, distort the terminal, or damage the mating part. Where fit evaluation is authorized, use the specified mating component and procedure and retain both parts. Functional fit evidence supplements the edge inspection; it does not replace a drawing requirement or prove long-term electrical performance.
Keep terminal geometry questions separate
A terminal can have the correct hole position and still present an edge concern. It can also have a smooth-looking edge while its hole or terminal plane is outside the required geometry. Refer to the separate terminal hole position inspection when the issue is location, and keep those results in a different field. This prevents an acceptable dimension from being misused as evidence that every terminal characteristic passed.
Similarly, the terminal coating thickness report guide addresses coating evidence, not burr acceptance. An appearance difference near a cut edge can prompt a coating question, but the visual observation alone does not establish coating thickness or substrate exposure. Request the appropriate evidence for the specific claim instead of broadening a local concern into an unsupported statement about the entire switch.

Decide what can be concluded from the available evidence
If the drawing defines an edge requirement and the inspection method can resolve it, compare the recorded observation with that requirement. Identify the revision, measurement result where applicable, and responsible reviewer. If the requirement is missing, report that acceptance is unresolved. A clear unresolved status is more useful than inventing a universal limit or rejecting an entire shipment because one photograph looks unusual.
A supplier review should distinguish an isolated damaged terminal from a repeated feature on parts made by the same process. Keep sample selection and quantity visible in the report. One selected sample can establish that a condition exists on that sample; it does not establish its frequency across the shipment. Any expanded screening or sampling decision should follow the agreed quality arrangement, with quarantined and inspected quantities recorded separately.
Do not approve uncontrolled deburring at receiving
Filing, grinding, clipping, or polishing an assembled switch terminal can remove coating, alter the mating geometry, or leave conductive particles near the housing. Those are reasons to seek an approved disposition, not predictions that every rework will fail. Ask who is authorized to define the process, what protection and cleaning are required, and which characteristics must be rechecked afterward.
Keep any reworked sample separate from untouched evidence. Record the original concern, the approved instruction, the person carrying it out, and the post-action results. An authorized replacement may be more practical than receiving-site rework, especially when the interface or plating requirements are not available. Never hide an edge alteration by replacing the original photographs with improved-looking images.
Send a supplier request that can produce a decision
A useful inquiry includes the order identity, terminal version, sample reference, overall and close-up photographs, inspection conditions, questioned zone, and relevant drawing clause. State whether the issue was observed before any connector insertion or cleaning. Ask the supplier to confirm the intended edge condition and propose acceptance, replacement, further measurement, or controlled rework against the ordered configuration.
Request a reply that refers to the same sample and lot, rather than a generic statement that the switch is good quality. If the supplier provides a new drawing or acceptance photograph, verify its revision and applicability before closing the record. Preserve the original evidence, final disposition, and any corrective action. This gives purchasing and assembly teams a usable conclusion without turning an appearance check into an unsupported certification claim.
Weiterbildung
This NPTEL lecture introduces optical microscopy modes, including reflected illumination. It supports understanding the viewing method for an opaque terminal, rather than defining KW7 acceptance requirements.
Häufig gestellte Fragen
Beweist eine glänzende Kante, dass es einen Grat gibt?
Nein. Eine Reflexion kann einer Projektion ähneln. Überprüfen Sie eine andere Lichtquelle und Blickwinkel, bewahren Sie die Originalbilder und messen Sie nur mit einer geeigneten vereinbarten Methode.
Kann eine Steckverbindereinfügungsprüfung die Kanteninspektion ersetzen?
Nr. Die Passformbewertung und die Kanteninspektion beantworten unterschiedliche Fragen. Verwenden Sie das angegebene Verbindungselement nur, wenn das Verfahren genehmigt ist, und vergleichen Sie jedes Merkmal mit seinen eigenen Anforderungen.
Was ist, wenn die KW7-Terminalzeichnung kein Gratlimit angibt?
Dokumentieren Sie die Beobachtung und fordern Sie eine anwendbare Akzeptanzanforderung vom Lieferanten an. Entleihen Sie keine numerischen Grenzen aus den Steckverbinderspezifikationen oder nicht verwandten Schaltermodellen.
Sollte das Empfangspersonal einen verdächtigen Grat ablegen?
Behalten Sie eine unberührte Probe und fordern Sie eine autorisierte Entsorgung an. Unkontrollierte Änderungen können Beschichtung, Geometrie und Schmutzbedingungen verändern und machen den erhaltenen Zustand schwerer zu untersuchen.